''This calibration is meant for Dragon A400 users experiencing differences in cutting height due to front gate offset issues while running '''square and rectangular tubing only.'''''
 
''This calibration is meant for Dragon A400 users experiencing differences in cutting height due to front gate offset issues while running '''square and rectangular tubing only.'''''
  
'''1.''' If you require a way to calibrate based on your tubing, the option is here for you located in the '''Tube/Pipe Library''' under the '''Advanced''' tab.
+
'''1.''' If you require a way to calibrate based on your tubing, the option is here for you located in the '''Tube/Pipe Library''' under the '''Advanced''' tab. You will have to select a square or rectangular tubing from the material list in order to change to the Advanced tab.
  
  
Line 25: Line 25:
  
  
'''4.''' The calibration window will appear and instruct you to make sure your machine has been powered '''off''' before continuing. You are free to move the chuck trolley manually to the front most position to accommodate a shorter length of tubing. '''IMPORTANT: Make sure the front gate is positioned to its HOME position before continuing.'''  
+
'''4.''' On this screen, you will be prompted to select your machine (usually named for its serial number) before continuing. Once the proper machine is selected, click the '''Next''' button.
  
 +
[[File:Side_Offsets_Calib4(1).png]]
  
[[File:Side_Offsets_Calib5.png]][[File:Side_Offsets_Calib5a.png]]
 
  
 +
'''5.''' Now, ensure that your machine is turned on and click the '''Start Mach''' button on the screen to turn on the Mach 3 software, or, in the case that it is already turned on, the calibration screen will acknowledge this and continue to the next step in the calibration process.
  
'''5.''' Obtain a dial indicator for the following steps. Proceed by placing the dial indicator on a surface that is considered '''constant''' (like the machine's beak/part catcher) and then set the indicator as shown in the picture and '''zero''' it out to start.
+
[[File:Side_Offsets_Calib4(2).png]]
 +
 
 +
 
 +
'''6.''' The calibration window will appear and instruct you to home your machine before continuing. Once it is completely home, the green lettering will disappear and you are free to click the '''Next''' button.  '''IMPORTANT: Make sure the front gate is positioned to its HOME position before continuing.'''
 +
 
 +
 
 +
[[File:Side_Offsets_Calib5(1).png]][[File:Side_Offsets_Calib5a.png]]
 +
 
 +
 
 +
 
 +
 
 +
'''7.''' Now, you will be prompted to indicate the length of the tubing by entering it into the provided value field, then click the '''Begin Load''' button to bring the chuck trolley to its load position for this length tube. Proceed to load the material and click the '''Next''' button once you've done so.
 +
 +
 
 +
[[File:Side_Offsets_Calib5.png]]
 +
 
 +
 
 +
'''8.''' Obtain a dial indicator for the following steps. Proceed by placing the dial indicator on a surface that is considered '''constant''' (like the machine's beak/part catcher) and then set the indicator as shown in the picture and '''zero''' it out to start.
  
  
Line 37: Line 55:
  
  
'''6.''' In this step you will rotate the tube 90 degrees as shown in the picture making sure not to move the dial indicator and take a new reading on this next face of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).
+
'''9.''' In this step you will rotate the tube 90 degrees as shown in the picture making sure not to move the dial indicator and take a new reading on this next face of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).
  
  
Line 43: Line 61:
  
  
'''7.''' Rotate the tubing an additional 90 degrees (180 from home now) and take another reading from the dial indicator on side 3 of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).
+
'''10.''' Rotate the tubing an additional 90 degrees (180 from home now) and take another reading from the dial indicator on side 3 of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).
  
  
Line 50: Line 68:
  
  
'''8.''' Rotate the tube a final 90 degrees and input the distance read from the dial indicator once again. (This can be a positive or negative value).  
+
'''11.''' Rotate the tube a final 90 degrees and input the distance read from the dial indicator once again. (This can be a positive or negative value).  
  
  
Line 56: Line 74:
  
  
'''9.''' Now, rotate the gate to its '''home position''' once again, reset the dial indicator located at the top side of the material and '''zero''' it out here and enter '''0''' in the input field before continuing to the next step.
+
'''12.''' Now, rotate the gate to its '''home position''' once again, reset the dial indicator located at the top side of the material and '''zero''' it out here and enter '''0''' in the input field before continuing to the next step.
  
  
Line 62: Line 80:
  
  
'''10.''' Rotate the tube 90 degrees as shown in the picture making sure not to move the dial indicator and take a new reading on this next face of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).
+
'''13.''' Rotate the tube 90 degrees as shown in the picture making sure not to move the dial indicator and take a new reading on this next face of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).
  
  
Line 68: Line 86:
  
  
'''11.''' Rotate the tubing an additional 90 degrees (180 from home now) and take another reading from the dial indicator on side 3 of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).
+
'''14.''' Rotate the tubing an additional 90 degrees (180 from home now) and take another reading from the dial indicator on side 3 of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).
  
  
Line 74: Line 92:
  
  
'''12.''' Rotate the tube a final 90 degrees and input the distance read from the dial indicator once again. (This can be a positive or negative value).  
+
'''15.''' Rotate the tube a final 90 degrees and input the distance read from the dial indicator once again. (This can be a positive or negative value).  
  
  
Line 80: Line 98:
  
  
'''13.''' This screen will show your newly complete calibration values for the material and will be applied to any new project made with this material.
+
'''16.''' This screen will show your newly complete calibration values for the material and will be applied to any new project made with this material.
  
  

Revision as of 11:20, 10 November 2017

Dragon A400 Side Offsets Calibration

This calibration is still in its testing phase and will be ready for use in Dragon A400 version 1.07.13.

This calibration is meant for Dragon A400 users experiencing differences in cutting height due to front gate offset issues while running square and rectangular tubing only.

1. If you require a way to calibrate based on your tubing, the option is here for you located in the Tube/Pipe Library under the Advanced tab. You will have to select a square or rectangular tubing from the material list in order to change to the Advanced tab.


Side Offsets Calib1.png

Side Offsets Calib2.png


2. In the Advanced tab, select the Calibration option under the Side Offsets section at the bottom of the window.


Side Offsets Calib3.png


3. The first screen is available to Disable any previously entered material side offsets (as an option) before continuing with the calibration. click Next to start the calibration process.


Side Offsets Calib4.png


4. On this screen, you will be prompted to select your machine (usually named for its serial number) before continuing. Once the proper machine is selected, click the Next button.

Side Offsets Calib4(1).png


5. Now, ensure that your machine is turned on and click the Start Mach button on the screen to turn on the Mach 3 software, or, in the case that it is already turned on, the calibration screen will acknowledge this and continue to the next step in the calibration process.

Side Offsets Calib4(2).png


6. The calibration window will appear and instruct you to home your machine before continuing. Once it is completely home, the green lettering will disappear and you are free to click the Next button. IMPORTANT: Make sure the front gate is positioned to its HOME position before continuing.


Side Offsets Calib5(1).pngSide Offsets Calib5a.png



7. Now, you will be prompted to indicate the length of the tubing by entering it into the provided value field, then click the Begin Load button to bring the chuck trolley to its load position for this length tube. Proceed to load the material and click the Next button once you've done so.


Side Offsets Calib5.png


8. Obtain a dial indicator for the following steps. Proceed by placing the dial indicator on a surface that is considered constant (like the machine's beak/part catcher) and then set the indicator as shown in the picture and zero it out to start.


Side Offsets Calib6.png


9. In this step you will rotate the tube 90 degrees as shown in the picture making sure not to move the dial indicator and take a new reading on this next face of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).


Side Offsets Calib7.png


10. Rotate the tubing an additional 90 degrees (180 from home now) and take another reading from the dial indicator on side 3 of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).


Side Offsets Calib8.png


11. Rotate the tube a final 90 degrees and input the distance read from the dial indicator once again. (This can be a positive or negative value).


Side Offsets Calib9.png


12. Now, rotate the gate to its home position once again, reset the dial indicator located at the top side of the material and zero it out here and enter 0 in the input field before continuing to the next step.


Side Offsets Calib10.png


13. Rotate the tube 90 degrees as shown in the picture making sure not to move the dial indicator and take a new reading on this next face of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).


Side Offsets Calib11.png


14. Rotate the tubing an additional 90 degrees (180 from home now) and take another reading from the dial indicator on side 3 of the tubing. The reading should be entered into the value field below. (This can be a positive or negative value).


Side Offsets Calib12.png


15. Rotate the tube a final 90 degrees and input the distance read from the dial indicator once again. (This can be a positive or negative value).


Side Offsets Calib13.png


16. This screen will show your newly complete calibration values for the material and will be applied to any new project made with this material.


Side Offsets Calib14.png

Side Offsets Calib15.png