Line 1: Line 1:
 +
'''"IMPORTANT: YOUR DRAGON A400 MACHINE HAS BEEN CALIBRATED AT OUR SHOP LOCATION. IF YOU HAVE NOT RECEIVED A BACKUP FILE, CONTACT YOUR BEND-TECH SUPPORT REPRESENTATIVE IMMEDIATELY TO DO SO."'''
 +
 +
'''"IN THE EVENT THAT YOU HAVE OBTAINED AND INSTALLED YOUR BACKUP FILE, YOU WILL ONLY NEED TO CALIBRATE YOUR TORCH POSITION IN THE WIZARD."'''
 +
 
'''"This guide will help you understand all of the processes and procedures involved in calibrating your Dragon A400 machine."'''
 
'''"This guide will help you understand all of the processes and procedures involved in calibrating your Dragon A400 machine."'''
  
 
'''"Please take your time in calibrating your new Dragon Machine/Software by following all of these steps thoroughly. This should take anywhere from 45 minutes to 2 hours based on how you pay attention to detail, how much help you have and if you are technologically adept or not."'''
 
'''"Please take your time in calibrating your new Dragon Machine/Software by following all of these steps thoroughly. This should take anywhere from 45 minutes to 2 hours based on how you pay attention to detail, how much help you have and if you are technologically adept or not."'''
 
'''"IMPORTANT: YOUR DRAGON A400 MACHINE HAS BEEN CALIBRATED AT OUR SHOP LOCATION. IF YOU HAVE NOT RECEIVED A BACKUP FILE, CONTACT YOUR BEND-TECH SUPPORT REPRESENTATIVE IMMEDIATELY TO DO SO."'''
 
 
'''"IN THE EVENT THAT YOU HAVE OBTAINED AND INSTALLED YOUR BACKUP FILE, YOU WILL ONLY NEED TO CALIBRATE YOUR TORCH POSITION IN THE WIZARD."'''
 
  
 
=Machine Library/Machine Setup=
 
=Machine Library/Machine Setup=
Line 15: Line 15:
  
 
'''2.''' Click on the '''Tools''' button from the '''[[Main Menu Bar]]''', then the '''Machine Library''' [[File:Mach_Lib_Icon1.png]] icon and select the '''Wizard''' [[File:Drag_Calibration_Help1.png]] button.
 
'''2.''' Click on the '''Tools''' button from the '''[[Main Menu Bar]]''', then the '''Machine Library''' [[File:Mach_Lib_Icon1.png]] icon and select the '''Wizard''' [[File:Drag_Calibration_Help1.png]] button.
 
'''3.''' Click on the '''Tools''' button from the '''[[Main Menu Bar]]''', then the '''Machine Setup''' button.
 
  
 
=Dragon Calibration Wizard=
 
=Dragon Calibration Wizard=
Line 485: Line 483:
  
 
*This page will prompt you to move the chuck near the back of the machine using the '''left''' and '''right''' buttons on your mouse followed the Next button.
 
*This page will prompt you to move the chuck near the back of the machine using the '''left''' and '''right''' buttons on your mouse followed the Next button.
 +
 +
  
  
Line 619: Line 619:
  
 
*Then, click the next button.
 
*Then, click the next button.
 
 
 
 
 
 
 
 
 
 
 
  
  
Line 774: Line 763:
  
 
*Then, click the next button.
 
*Then, click the next button.
 +
 +
  
  
Line 854: Line 845:
  
  
=Toolset Calibration=
 
[[File:Dragon_Calibration_Marker_Alignment_X_Axis1.png|right]]
 
  
*This page will prompt you to load the material used for this calibration, making sure to locate the end of the tubing a few inches past the laser positioning light.
 
 
*Enter the OD of the tubing into the '''Tube OD''' value field and click the next button to continue.
 
  
  
  
  
 +
=Select Material Type=
 +
[[File:Dragon_A400_Calibration_Select_Material1.png|right]]
  
 +
*This page will prompt you to select the material type that will be used for calibrating your tools on the toolhead. This can be either round, square or rectangular material.
  
 +
*Then, click the next button.
  
  
Line 897: Line 887:
  
  
=Front Holding Gate Operation=
 
[[File:Dragon_Calibration_Marker_Alignment_X_Axis2.png|right]]
 
  
*Click the wording that reads '''Click here to see how the front holding gate works''' and a window will appear showing you how to adjust the front gate to accommodate your tubing OD.
 
  
  
Line 911: Line 898:
  
  
 +
=Loading Material=
 +
[[File:Dragon_A400_Calibration_Load_Material1.png|right]]
  
 +
*This page will prompt you to click the Begin Load button, load your material with 3 inches or so sticking out past the laser and input the height or OD of your material in the Material Height value field provided.
  
 +
*Then, click the next button.
  
  
Line 942: Line 933:
  
  
=Laser Calibration - Step 1=
 
[[File:Dragon_Calibration_Marker_Height_Adjustment1.png|right]]
 
 
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the laser left and right until it touches the left most edge of the tubing.
 
  
*Next, press the next button to register the information with the software and continue.
 
  
  
Line 957: Line 943:
  
  
 +
=Front Holding Gate Operation=
 +
[[File:Dragon_A400_Calibration_Gate_Alignment1.png|right]]
  
 +
*Click the wording that reads '''Click here to see how the front holding gate works''' and a window will appear showing you how to adjust the front gate to accommodate your tubing OD.
  
  
Line 982: Line 971:
  
  
=Laser Calibration - Step 2=
 
[[File:Dragon_Calibration_Marker_Calibration_Verify1.png|right]]
 
  
  
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the laser left and right until it touches the right most edge of the tubing.
 
  
*Next, press the next button to register the information with the software and continue.
 
  
  
Line 1,005: Line 990:
  
  
 +
=Laser Calibration - Step 1=
 +
[[File:Dragon_A400_Calibration_Laser_Adjustment1.png|right]]
  
 +
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the laser left and right until it touches the left most edge of the tubing.
  
 +
*Next, press the next button to register the information with the software and continue.
  
  
Line 1,023: Line 1,012:
  
  
=Laser Calibration - Step 3=
 
[[File:Dragon_calibration_Engraver_Centering1.png|right]]
 
  
*This page automatically use the information from the two previous steps and attempt to find the center of the tubing.
 
  
*If the location of the laser is not completely centered on the tube, repeat the previous steps to ensure an accurate calibration, then mark the absolute center with a marker.
 
  
*Then, click the next button to continue.
 
  
  
Line 1,052: Line 1,036:
  
  
 +
=Laser Calibration - Step 2=
 +
[[File:Dragon_A400_Calibration_Laser_Calibration2.png|right]]
  
  
 +
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the laser left and right until it touches the right most edge of the tubing.
  
 +
*Next, press the next button to register the information with the software and continue.
  
  
Line 1,063: Line 1,051:
  
  
=Pen Calibration - Step 1=
 
[[File:Dragon_Calibration_Engraver_Alignment_X_Axis1.png|right]]
 
  
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the marker perpendicular to the length of the tubing (Z-Axis) until it lines up with the mark you've created on the center of the tubing. Then, press the next button to register the information with the software.
 
  
  
Line 1,095: Line 1,080:
  
  
 +
=Laser Calibration - Step 3=
 +
[[File:Dragon_A400_calibration_Laser_Adjustment3.png|right]]
  
 +
*This page automatically use the information from the two previous steps and attempt to find the center of the tubing.
  
 +
*If the location of the laser is not completely centered on the tube, repeat the previous steps to ensure an accurate calibration, then mark the absolute center with a marker.
  
 +
*Then, click the next button to continue.
  
  
  
=Pen Calibration - Step 2=
 
[[File:Dragon_Calibration_Engraver_Height_Adjustment1.png|right]]
 
  
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the marker along the length of the tubing (X-Axis) until it lines up with the mark in the center of the tubing. Then, press the next button to register the information with the software.
 
  
  
Line 1,136: Line 1,123:
  
  
 +
=Pen Calibration=
 +
[[File:Dragon_A400_Calibration_Marker_Alignment1.png|right]]
  
 +
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the marker up, down, left and right, and feed the tubing forward or backward until it lines up with the mark you've created on the center of the tubing. Then, press the next button to register the information with the software.
  
  
  
=Pen Calibration - Step 3=
 
[[File:Dragon_Calibration_Engraver_Calibration_Verify1.png|right]]
 
  
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the marker vertically (X-Axis) to meet with the mark in the center of the tubing. Then, press the next button to register the information with the software.
 
  
  
Line 1,177: Line 1,164:
  
  
=Adjust Pen=
 
[[File:Dragon_Calibration_Torch_Centering1.png|right]]
 
  
*This page will prompt you to use the '''red arrow''' buttons to move the laser left, right, forward and backward to find the center of the mark on the tubing.
+
=Engraver Calibration=
 +
[[File:Dragon_A400_Calibration_Engraver_Alignment1.png|right]]
  
*Then, press the next button to register the information with the software.
+
*This page will prompt you to first initiate the engraver using the Start Engraver button, then use the '''left''' and '''right''' buttons on your mouse to move the engraver up, down, left and right, and feed the tubing forward or backward until it lies directly on the mark you've created on the center of the tubing. Then, press the next button to register the information with the software.
  
  
Line 1,215: Line 1,201:
  
  
=Engraver Calibration - Step 1=
 
[[File:Dragon_Calibration_Torch_Alignment_X_Axis1.png|right]]
 
  
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the engraver perpendicular to the length of the tubing (Z-Axis) until it lines up with the mark you've created on the center of the tubing. Then, press the next button to register the information with the software.
 
  
  
  
  
 +
=Torch Calibration=
 +
[[File:Dragon_A400_Calibration_Torch_Alignment1.png|right]]
  
 +
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the torch up, down, left and right, and feed the tubing forward or backward until it lies directly on the mark you've created on the center of the tubing. Then, press the next button to register the information with the software.
  
  
Line 1,253: Line 1,239:
  
  
=Engraver Calibration - Step 2=
 
[[File:Dragon_calibration_Torch_Height_Adjustment1.png|right]]
 
  
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the engraver along the length of the tubing (X-Axis) until it lines up with the mark in the center of the tubing. Then, press the next button to register the information with the software.
 
  
  
Line 1,267: Line 1,250:
  
  
 +
=Pierce Hole=
 +
[[File:Dragon_A400_Calibration_Torch_Alignment2.png|right]]
  
 +
*This page will prompt you to click the Pierce Hole button above to cause the torch to gouge or pierce a hole into the top face of your material. Ensure that your torch is turned on and that you have proper air and amperage to the plasma power source. Amperage is irrelevant for the most part. Whether there is a divot or an actual hole, this will work for our purposes in the next step.
  
 +
*Click the next button to continue.
  
  
Line 1,295: Line 1,282:
  
  
=Engraver Calibration - Step 3=
 
[[File:Dragon_Calibration_Torch_Calibration_Verify1.png|right]]
 
  
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the engraver vertically (X-Axis) to meet with the mark in the center of the tubing. Then, press the next button to register the information with the software.
 
  
  
Line 1,308: Line 1,292:
  
  
 +
=Hole Verification=
 +
[[File:Dragon_A400_Hole_Pierce_Verification1.png|right]]
  
 +
*This page will prompt you to move the toolset and chuck trolley to validate the position of the laser over the pierce hole and see if you need to make adjustments.
  
 +
*When you're sure that the torch has been calibrated correctly, click the finish button to lock in the information.
  
  
Line 1,321: Line 1,309:
  
  
 
 
 
 
 
 
 
 
 
 
=Adjust Engraver=
 
[[File:Dragon_Calibration_Adjust_Engraver1.png|right]]
 
 
*This page will prompt you to use the '''red arrow''' buttons to move the laser left, right, forward and backward to find the center of the mark on the tubing.
 
 
*Then, press the next button to register the information with the software.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
=Torch Calibration - Step 1=
 
[[File:Dragon_Calibration_Torch_Alignment_X_Axis2.png|right]]
 
 
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the torch perpendicular to the length of the tubing (Z-Axis) until it lines up with the mark you've created on the center of the tubing. Then, press the next button to register the information with the software.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
=Torch Calibration - Step 2=
 
[[File:Dragon_calibration_Torch_Height_Adjustment2.png|right]]
 
 
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the torch along the length of the tubing (X-Axis) until it lines up with the mark in the center of the tubing. Then, press the next button to register the information with the software.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
=Torch Calibration - Step 3=
 
[[File:Dragon_Calibration_Torch_Calibration_Verify2.png|right]]
 
 
*This page will prompt you to use the '''left''' and '''right''' buttons on your mouse to move the torch vertically (X-Axis) to meet with the mark in the center of the tubing. Then, press the next button to register the information with the software.
 
  
  
Line 1,470: Line 1,334:
  
  
 +
=Lifter Station Material Gap=
 +
[[File:dragon_A400_Calibration_B_Axis4.png|right]]
  
 +
*This page will prompt you to click on the Move Trolley button above to move the chuck trolley to the lifter station location, then click in the picture on the screen to move your lifter head upwards to come in contact with the material that's been loaded.
  
 +
*Then, click the next button.
  
  
  
=Adjust Torch=
 
[[File:Dragon_Calibration_Adjust_Engraver2.png|right]]
 
  
*This page will prompt you to use the '''red arrow''' buttons to move the laser left, right, forward and backward to find the center of the mark on the tubing.
 
  
*Then, press the next button to register the information with the software.
 
  
  
Line 1,513: Line 1,377:
  
  
=Toolset Verification=
 
[[File:Dragon_Something_Whatever_This_Sucks_And_Im_Glad_Its_Over1.png|right]]
 
  
*This last window will prompt you to move each of the tools on the toolset to validate their position and see if you need to make adjustments to any of them.
+
=Calibration Complete=
 +
[[File:Dragon_A400_Calibration_Complete1.png|right]]
  
*When you're sure that the tools have all been calibrated correctly, click the finish button to lock in the information and close the calibration wizard.
+
*Click the Done button to close the wizard and accept the values.

Latest revision as of 13:45, 20 November 2017

"IMPORTANT: YOUR DRAGON A400 MACHINE HAS BEEN CALIBRATED AT OUR SHOP LOCATION. IF YOU HAVE NOT RECEIVED A BACKUP FILE, CONTACT YOUR BEND-TECH SUPPORT REPRESENTATIVE IMMEDIATELY TO DO SO."

"IN THE EVENT THAT YOU HAVE OBTAINED AND INSTALLED YOUR BACKUP FILE, YOU WILL ONLY NEED TO CALIBRATE YOUR TORCH POSITION IN THE WIZARD."

"This guide will help you understand all of the processes and procedures involved in calibrating your Dragon A400 machine."

"Please take your time in calibrating your new Dragon Machine/Software by following all of these steps thoroughly. This should take anywhere from 45 minutes to 2 hours based on how you pay attention to detail, how much help you have and if you are technologically adept or not."

Machine Library/Machine Setup

  • After opening the Bend-Tech CAM software, choose either one of these steps to enter the machine calibration page.

1. Click directly on the Machine Library Mach Lib Icon1.png icon from the right hand side of the Task Menu screen and select the Wizard Drag Calibration Help1.png button.

Drag Tools Mach Lib1.png Drag Tools Mach Setup1.png

2. Click on the Tools button from the Main Menu Bar, then the Machine Library Mach Lib Icon1.png icon and select the Wizard Drag Calibration Help1.png button.

Dragon Calibration Wizard

This initial startup screen for the Calibration Wizard will allow you to choose from multiple options for calibrating different aspects of your machine, or complete an overall calibration from the beginning.

Dragon A400 Calibration Wizard1.png

Introduction

Dragon A400 Calibration Introduction1.png
  • This introduction gives you a small insight into the tasks that are expected during this calibration and instructs you to turn on the power on the Dragon machine.
  • When the machine is turned on, click the "Start Mach" button to continue to the next page.




















Select Computer Setup

Dragon A400 Calibration Basic Ass1.png
  • The "Select Computer Setup" page will open your Mach program and it will ask you which side of the Dragon machine your computer is located on.
  • Select the image that describes your computer's location in reference to the Dragon machine to move on to the next page in the calibration.



















Chuck Travel (X Axis)

Dragon A400 Calibration X Axis1.png
  • This page will prompt you to adjust the chuck travel to ensure that it is moving in the proper direction when you press the left and right buttons on your mouse.























Chuck Rotation (Y Axis)

Dragon A400 Y Axis Movement Chuck Rotation1.png
  • This page will prompt you to adjust the chuck rotation to ensure that it is rotating in the proper direction when you press the left and right buttons on your mouse.























Toolset Horizontal Control (Z Axis)

Dragon A400 Calibration Z Axis Movement Tool Height.png
  • This page will prompt you to move the tool head horizontally to ensure that the toolset is moving in the proper direction when you press the left and right buttons on your mouse.





















Toolset Vertical Control (A Axis)

Dragon A400 Calibration A Axis Movement Tool Change1.png
  • This page will prompt you to adjust the toolset's vertical movement to ensure that it is moving in the proper direction when you press the left and right buttons on your mouse.























Lifter Station Control (B Axis)

Dragon A400 Calibration B Axis1.png
  • This page will prompt you to move the lifter station and ensure that it is moving in the proper direction when you press the left and right buttons on your mouse.





















Check Homing Switch (X Axis)

Dragon A400 Calibration Axis Homing1.png
  • The page will prompt you to place a piece of metal to the manual switch for the X axis at the rear of the machine rail. You are prompted to activate this X axis switch until the screen indicator changes from Inactive to Active before clicking the Next button.






















Check Homing Switch (Z Axis)

Dragon A400 Calibration Axis Homing2.png
  • The page will prompt you to place a piece of metal to the manual switch for the Z axis at the head of the machine on the horizontal axis. You are prompted to activate this Z axis switch until the screen indicator changes from Inactive to Active before clicking the Next button.






















Check Homing Switch (A Axis)

Dragon A400 Calibration Axis Homing3.png
  • The page will prompt you to place a piece of metal to the manual switch for the A axis at the head of the machine on the vertical axis. You are prompted to activate this A axis switch until the screen indicator changes from Inactive to Active before clicking the Next button.





















Rapid Travel

Dragon A400 Calibration rapid travel1.png
  • This page will prompt you to move the chuck near the back of the machine using the left and right buttons on your mouse followed the Next button.






















Homing the Machine

Dragon A400 Calibration Homing Machine1.png
  • This page will prompt you to click anywhere in the picture in order to send the machine to its home position.
  • Then, click the next button.






















Zero Chuck Rotation (Y Axis) - Step 1

Dragon A400 Calibration Zero Chuck1.png
  • This page will prompt you to place an angle gauge or level onto the tool head rail located directly behind the tool changer. Then, zero out the angle gauge or read the bubble location on your level and note the value for use in the next step.
  • Then, click the next button.


















Zero Chuck Rotation (Y Axis) - Step 2

Dragon A400 Calibration Zero Chuck2.png
  • This page will prompt you to place your angle gauge or level and place it on the fingers of the chuck. Then, rotate the chuck using the left and right click buttons on your mouse until the angle gauge or level reads as it did on the rail from the previous step.
  • Then, click the next button.




















Lifter Station Switch

Dragon A400 Calibration B Axis2.png
  • This page will prompt you to click on the Move Lifter button, then slowly jog the lifter head down until it triggers the switch and moves out of the way.
  • Then, click the next button.






















Lifter Station Location

Dragon A400 Calibration B Axis3.png
  • This page will prompt you to click on the picture in the screen to move your chuck trolley 1-2 inches from the lifter head.
  • Then, click the next button.























Maximum Chuck Travel (X Axis)

Dragon A400 Calibration Chuck Max Travel1.png
  • This page will prompt you to click in the picture on the screen in order to position the chuck near the front gate. Then, back the chuck off so that the jaws of the chuck are lined up with the rear face of the front gate.
  • Then, click the next button.























Dead Zone Length

Dragon A400 Calibration Laser Centering1.png
  • This page will prompt you to measure the length from the base of the chuck to the laser light when the chuck is in its front most position.
  • Enter the measured length in the Deadzone Length value field and select the next button when you're finished.



















Select Material Type

Dragon A400 Calibration Select Material1.png
  • This page will prompt you to select the material type that will be used for calibrating your tools on the toolhead. This can be either round, square or rectangular material.
  • Then, click the next button.






















Loading Material

Dragon A400 Calibration Load Material1.png
  • This page will prompt you to click the Begin Load button, load your material with 3 inches or so sticking out past the laser and input the height or OD of your material in the Material Height value field provided.
  • Then, click the next button.




















Front Holding Gate Operation

Dragon A400 Calibration Gate Alignment1.png
  • Click the wording that reads Click here to see how the front holding gate works and a window will appear showing you how to adjust the front gate to accommodate your tubing OD.






















Laser Calibration - Step 1

Dragon A400 Calibration Laser Adjustment1.png
  • This page will prompt you to use the left and right buttons on your mouse to move the laser left and right until it touches the left most edge of the tubing.
  • Next, press the next button to register the information with the software and continue.





















Laser Calibration - Step 2

Dragon A400 Calibration Laser Calibration2.png


  • This page will prompt you to use the left and right buttons on your mouse to move the laser left and right until it touches the right most edge of the tubing.
  • Next, press the next button to register the information with the software and continue.



















Laser Calibration - Step 3

Dragon A400 calibration Laser Adjustment3.png
  • This page automatically use the information from the two previous steps and attempt to find the center of the tubing.
  • If the location of the laser is not completely centered on the tube, repeat the previous steps to ensure an accurate calibration, then mark the absolute center with a marker.
  • Then, click the next button to continue.


















Pen Calibration

Dragon A400 Calibration Marker Alignment1.png
  • This page will prompt you to use the left and right buttons on your mouse to move the marker up, down, left and right, and feed the tubing forward or backward until it lines up with the mark you've created on the center of the tubing. Then, press the next button to register the information with the software.




















Engraver Calibration

Dragon A400 Calibration Engraver Alignment1.png
  • This page will prompt you to first initiate the engraver using the Start Engraver button, then use the left and right buttons on your mouse to move the engraver up, down, left and right, and feed the tubing forward or backward until it lies directly on the mark you've created on the center of the tubing. Then, press the next button to register the information with the software.



















Torch Calibration

Dragon A400 Calibration Torch Alignment1.png
  • This page will prompt you to use the left and right buttons on your mouse to move the torch up, down, left and right, and feed the tubing forward or backward until it lies directly on the mark you've created on the center of the tubing. Then, press the next button to register the information with the software.





















Pierce Hole

Dragon A400 Calibration Torch Alignment2.png
  • This page will prompt you to click the Pierce Hole button above to cause the torch to gouge or pierce a hole into the top face of your material. Ensure that your torch is turned on and that you have proper air and amperage to the plasma power source. Amperage is irrelevant for the most part. Whether there is a divot or an actual hole, this will work for our purposes in the next step.
  • Click the next button to continue.



















Hole Verification

Dragon A400 Hole Pierce Verification1.png
  • This page will prompt you to move the toolset and chuck trolley to validate the position of the laser over the pierce hole and see if you need to make adjustments.
  • When you're sure that the torch has been calibrated correctly, click the finish button to lock in the information.



















Lifter Station Material Gap

Dragon A400 Calibration B Axis4.png
  • This page will prompt you to click on the Move Trolley button above to move the chuck trolley to the lifter station location, then click in the picture on the screen to move your lifter head upwards to come in contact with the material that's been loaded.
  • Then, click the next button.




















Calibration Complete

Dragon A400 Calibration Complete1.png
  • Click the Done button to close the wizard and accept the values.